Product Code : ACS-181
Product Description

Power Amplifiers

Model No : ACS-230-25W

Feature

  • 150 kHz - 230 MHz
  • IEC 61000-4-6 testing
  • 25 Watts
  • 3 Year Warranty

Specification

Frequency Range

150 kHz to 230 MHz

Rated Power Output

25 watts into 2:1 VSWR

Gain

43 dB ±2 dB

Input for rated output

0 dBm (typical)

Automatic Safety Shut-off

30 watts ± 2

Power Output @ 1 dB Compression Point

N/A

Input:

Impedance

50 ohms (nominal)

VSWR

1.7 (maximum)

Input Signal Modulation Compatibility

AM, FM, or Pulse modulation

Connector: 

Type N on Front Panel

Output:

Impedance

50 ohms (nominal)

VSWR

1.7 (maximum)

Harmonic distortion

-20 dBc at 25 watts

Mismatch Tolerance

Automatic Safety Shut-off @ VSWR >7

Connector

Type N on Front Panel

Power:

AC, Single Phase

100-240 VAC 50/60 Hz

Display and Interfaces:

Front Panel Display (Column 1)

Amplifier Current measurement Data

Front Panel Display (Column 2)

Amplifier Temperature measurement data

Front Panel Display (Column 3)

Load VSWR, RF Power Input/Output, Gain

Remote Interlock (optional)

2-pin DIN

Mechanical:

Cooling

Forced air (self-contained fans)

Size

19” Rack 2U

Weight

25 lbs (11.3 kg)

Operating Temperature Range

0° C to +40° C

 

Model No : ACS-230-50W

Feature

  • 150 kHz - 230 MHz
  • 50 Watts
  • 3 Year Warranty

Specification

Frequency Range

150 kHz to 230 MHz

Rated Power Output

50 watts into 2:1 VSWR

Gain

47 dB ±2 dB

Input for rated output

0 dBm (typical)

Automatic Safety Shut-off

50 watts ± 2

Power Output @ 1 dB Compression Point

N/A

Input:

Impedance 50 ohms (nominal)

VSWR

1.7 (maximum)

Input Signal Modulation Compatibility

AM, FM, or Pulse modulation

Connector

Type N on Front Panel

Output:

Impedance

50 ohms (nominal)

VSWR

1.7 (maximum)

Harmonic distortion

-17 dBc at 50 watts

Mismatch Tolerance

Automatic Safety Shut-off @ VSWR >7

Connector

Type N on Front Panel

Power: (Universal)

AC, Single Phase

100-240 VAC 50/60 Hz

Display and Interfaces

USB Remote Interface

Front Panel Display (Column 1)

Amplifier Current measurement Data

Front Panel Display (Column 2)

Amplifier Temperature measurement data

Front Panel Display (Column 3)

Load VSWR, RF Power Input/Output, Gain

Remote Interlock (optional)

2-pin DIN

Mechanical:

Cooling

Forced air (self-contained fans)

Size

19” Rack 4U

Weight

50 lbs (22.6 kg)

Operating Temperature Range

0° C to +40° C

 

Model No : ACS-250-100W

Feature

  • 150 KHz - 250 MHz
  • 100 Watts
  • 3 year warranty

Specification

Frequency Range

150 kHz to 250 MHz

Rated Power Output

100 watts into 2:1 VSWR

Gain

50 dB ±2 dB

Input for rated output

0 dBm (typical)

Automatic Safety Shut-off

140 watt

Power Output @ 1 dB Compression Point

No Compression unit 100 W

Input:

Impedance 50 ohms (nominal)

VSWR

1.7 (maximum

Input Signal Modulation Compatibility

AM, FM, or Pulse modulation

Connector

Type N on Front Panel

Output:

Impedance

50 ohms (nominal)

VSWR

1.7 (maximum)

Harmonic distortion

15 dBc at 50 watts

Mismatch Tolerance

Automatic Safety Shut-off @ VSWR >7

Connector

Type N on Front Panel

Power: (Universal)

AC, Single Phase

100-240 VAC 50/60 Hz

Display and Interfaces

USB Remote Interface

Front Panel Display (Column 1)

Amplifier Current measurement Data

Front Panel Display (Column 2)

Amplifier Temperature measurement data

Front Panel Display (Column 3)

Load VSWR, RF Power Input/Output, Gain

Remote Interlock (optional)

2-pin DIN

Mechanical:

Cooling

Forced air (self-contained fans)

Size

19” Rack 4U

Weight

47 lbs (21.4 kg)

Operating Temperature Range

0° C to +40° C

 

Model No : AFM-1500

Feature
  • 87.5 MHz - 108 MHz
  • 1500 Watts
  • 3 years warranty
  • CPAAT
  • CPAS
  • USB Interface

Specification

Frequency Range

87.5 kHz to 108 MHz

Rated Power Output

1500 watts

Input for rated output

2.5 Watts (max)

RF Checkpoint at output

0.707 Vrms (+10 dBm max.)

Input:

Impedance 50 ohms (nominal)


VSWR

1.2:1 (maximum)

Input Signal Modulation Compatibility

FM

Connector

Type BNC on Rear Panel

Output:

Impedance

50 ohms (nominal)

VSWR

1.2:1 (maximum)

Harmonic distortion

65 dBc (min) at 1500 watts

Mismatch Tolerance

Automatic Safety Shut-off @ VSWR >1.8

Connector

Type 7/16” on front panel

Power:

Power Amplifier Supply

27 VDC, 100 A (external)

Controller Supply

+/- 12 VDC, 1 A (external)

Power Consumption

2200 Watts (max)

Efficiency

68% (min)

Display and Interfaces

USB Remote Interface

Front Panel Display (Column 1)

Individual Modules current measurement data

Front Panel Display (Column 2)

Individual Modules temperature measurement data

Front Panel Display (Column 3)

Load VSWR, RF Power Input/Output, Gain

Mechanical:

Cooling

Forced air (self-contained fans)

Size

19” Rack 3U

Weight

75 lbs (34 kg)

Operating Temperature Range

0° C to 30° C

 

Model No : ARI-300K

Feature

  • Frequency Range: DC to 300 kHz
  • Up to 300 Watts Output Power into 1 or 2 ohms with less than 0.3% distortion
  • Protection Circuitry from Input Overload, Over-Temperature & Over-Current
  • Three-Year Warranty

Specification

GENERAL

Products Description

Power Amplifier

Application

Conducted/Radiated Susceptibility Testing

Standards

MIL-STD-461, RTCA DO-160, etc.

Frequency Range

DC to 300 kHz

Output Power

(see ‘ARI-300K Min. Power Output Specifications’ graph)

Input Impedance

10 kΩ (nominal)

Output Impedance

6.25 mΩ (nominal)

Output Voltage

(see ‘ARI-300K Min. Voltage Output Specifications’ graph)

Distortion

≤0.3%

DC Drift

< ±1.5 mV (after 30 minutes of operation)

Phase Response

< ±1.5 mV (after 30 minutes of operation)

ELECTRICAL

AC Input Power

100-250 Volts AC (50/60 Hz) 1000 VA (maximum)

INPUT/OUTPUT CONNECTORS

Input Connector

BNC (female)

Output Connectors

(2) x 4 mm Banana Jack Binding Posts

AC Input Connector

IEC C13 Receptable

ENVIRONMENTAL

Operating Temperature

40° F to 104° F (5° C to 40° C)

Cooling

Forced Air

MECHANICAL

Dimensions(HxWxD)

6.125” x 19” x 23.25” (15.9 cm x 48.3 cm x 59 cm)

Rack Mount Dimensions
(top/bottom feet removed, not including front handles)

(3U) 5.25” x 19” x 22.25” (13.34 cm x 48.3 cm x 56.5 cm)

 

Model No : ACS-181

Feature

  • Immunity Testing
  • IEC 61000-4-6 testing
  • 100 Watts
  • 3 Year Warranty

Specification

Frequency Range

150 kHz to 80 MHz

Rated Power Output

100 watts into 2:1 VSWR

Gain

50 dB ±2 dB

Input for rated output

0 dBm (typical)

Automatic Safety Shut-off

125 watts ± 2

Power Output @ 1 dB Compression Point

N/A

Input:

Impedance

50 ohms (nominal)

VSWR

1.7 (maximum)

Input Signal Modulation Compatibility

AM, FM, or Pulse modulation

Connector

Type N on Front Panel 

Output:

Impedance

50 ohms (nominal)

VSWR

1.7 (maximum)

Harmonic distortion

-15 dBc at 75 watts

Mismatch Tolerance

Automatic Safety Shut-off @ VSWR >5

Connector

Type N on Front Panel

Power: (Universal)

AC, Single Phase

100-240 VAC 50/60 Hz

Display and Interfaces

USB Remote Interface

Front Panel Display (Column 1)

Amplifier Current measurement Data

Front Panel Display (Column 2)

Amplifier Temperature measurement data

Front Panel Display (Column 3)

Load VSWR, RF Power Input/Output, Gain

Remote Interlock (optional)

2-pin DIN

Mechanical:

Cooling

Forced air (self-contained fans)

Size

19” Rack 4U

Weight

50 lbs (22.6 kg)

Operating Temperature Range

0° C to +40° C