Cookie Img
Mobile : +17146004253
Home » Products » Coupling - Decoupling Networks

Coupling - Decoupling Networks

We are offering a large variety of Coupling - Decoupling Networks for utilizing in various applications. Coupling devices are used to deliver common mode current disturbance signal to the EUT whereas decoupling networks insure that auxiliary equipments are not being influenced by disturbance signals. We have made them using advanced technology and have a huge variety. You can select these coupling - decoupling networks from us at affordable rates.      These are available in different types viz T2E, C50E, AF2E, M125E, T4E, AF4E, etc. Generally, all the products are as per the  IEC / EN 61000-4-6 quality standards.
Coupling - Decoupling Networks  -T2E
close
Coupling - Decoupling Networks -T2E
01
  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC / EN 61000-4-6
  • Application: One unscreened, balanced pair
  • Frequency Range: 150 kHz to 230 MHz
  • RF Input Voltage: 40 V (Max)
  • RF Input Connector: 50 Ω BNC (Female)
  • Voltage Rating: 124 V AC / 125 V DC (Line to Ground)
  • Current Rating: 2 Amps (Max)
  • AE and EUT Connections: RJ 11
Coupling - Decoupling Networks  C50E
close
Coupling - Decoupling Networks C50E
01
  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC / EN 61000-4-6
  • Application: 50 Ohm Coaxial Cables
  • Frequency Range: 150 kHz to 230 MHz
  • RF Input Voltage: 40 V (Max)
  • RF Input Connector: 50 Ω BNC (Female)
  • Voltage Rating: 310 V AC / 440 V DC (Line to Ground)
  • Current Rating: 1 Amp (Max)
  • AE and EUT Connections: 50 Ohm Female BNC
Coupling - Decoupling Networks AF2E
close
Coupling - Decoupling Networks AF2E
01
  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC / EN 61000-4-6
  • Application: Two wire unscreened, unbalanced Cables
  • Frequency Range: 150 kHz to 230 MHz
  • RF Input Voltage: 40 V (Max)
  • RF Input Connector: 50 Ω BNC (Female)
  • Voltage Rating: 310 V AC / 440 V DC (Line to Ground)
  • Current Rating: 5 Amp (Max)
  • AE and EUT Connections: 2 mm shrouded banana sockets
Coupling - Decoupling Networks -M125E
close
Coupling - Decoupling Networks -M125E
01
  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC / EN 61000-4-6
  • Application: Single conductor power cable
  • Frequency Range: 150 kHz to 230 MHz
  • RF Input Voltage: 40 V (Max)
  • RF Input Connector: 50 Ω BNC (Female)
  • Voltage Rating: 250 V AC / 350 V DC (Line to Ground)
  • Current Rating: 25 Amps AC / 17 Amps DC (Max)
  • AE and EUT Connections: 4 mm shrouded banana sockets
Coupling - Decoupling Networks  T4E
close
Coupling - Decoupling Networks T4E
02
  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC / EN 61000-4-6
  • Application: Two unscreened, balanced pair
  • Frequency Range: 150 kHz to 230 MHz
  • RF Input Voltage: 40 V (Max)
  • RF Input Connector: 50 Ω BNC (Female)
  • Voltage Rating: 124 V AC / 125 V DC (Line to Ground)
  • Current Rating: 2 Amps (Max)
  • AE and EUT Connections: RJ 45
Coupling - Decoupling Networks AF4E
close
Coupling - Decoupling Networks AF4E
02
  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC / EN 61000-4-6
  • Application: Four wire unscreened, unbalanced Cables
  • Frequency Range: 150 kHz to 230 MHz
  • RF Input Voltage: 40 V (Max)
  • RF Input Connector: 50 Ω BNC (Female)
  • Voltage Rating: 310 V AC / 440 V DC (Line to Ground)
  • Current Rating: 5 Amp (Max)
  • AE and EUT Connections: 2 mm shrouded banana sockets
Coupling - Decoupling Networks C75E
close
Coupling - Decoupling Networks C75E
02
  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC / EN 61000-4-6
  • Application: 75 Ohm Coaxial Cables
  • Frequency Range: 150 kHz to 230 MHz
  • RF Input Voltage: 40 V (Max)
  • RF Input Connector: 50 Ω BNC (Female)
  • Voltage Rating: 310 V AC / 440 V DC (Line to Ground)
  • Current Rating: 1 Amp (Max)
  • AE and EUT Connections: 75 Ohm Female BNC
Coupling - Decoupling Networks M225E
close
Coupling - Decoupling Networks M225E
02
  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC / EN 61000-4-6
  • Application: Two conductor power cable
  • Frequency Range: 150 kHz to 230 MHz
  • RF Input Voltage: 40 V (Max)
  • RF Input Connector: 50 Ω BNC (Female)
  • Voltage Rating: 250 V AC / 350 V DC (Line to Ground)
  • Current Rating: 25 Amps AC / 17 Amps DC (Max)
  • AE and EUT Connections: 4 mm shrouded banana sockets
Coupling - Decoupling Networks T8E
close
Coupling - Decoupling Networks T8E
03
  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC / EN 61000-4-6
  • Application: Four unscreened, balanced pair
  • Frequency Range: 150 kHz to 230 MHz
  • RF Input Voltage: 40 V (Max)
  • RF Input Connector: 50 Ω BNC (Female)
  • Voltage Rating: 124 V AC / 125 V DC (Line to Ground)
  • Current Rating: 1.5 Amps (Max)
  • AE and EUT Connections: RJ 45
Coupling - Decoupling Networks AF8E
close
Coupling - Decoupling Networks AF8E
03
  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC / EN 61000-4-6
  • Application: Eight wire unscreened, unbalanced cables
  • Frequency Range: 150 kHz to 230 MHz
  • RF Input Voltage: 40 V (Max)
  • RF Input Connector: 50 Ω BNC (Female)
  • Voltage Rating: 310 V AC / 440 V DC (Line to Ground)
  • Current Rating: 5 Amp (Max)
  • AE and EUT Connections: 2 mm shrouded banana sockets
Coupling - Decoupling Networks M250E
close
Coupling - Decoupling Networks M250E
03
  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC -61000-4-6, CISPR 16-1-2
  • Frequency Range: 150 kHz to 230 MHz
  • I/O rating for EUT/AE Ports: 250 VAC, 350 VDC
  • Max Input Voltage: 40 V
  • Application: Two wire power cables
  • Current rating: 50 Amps (AC), 35 Amps (DC)
  • RF Input Connector: 50 Ω BNC (female)
  • I/O Connection: 5.2 mm banana socket with shrouded Sheath
Coupling - Decoupling Networks T8SE
close
Coupling - Decoupling Networks T8SE
03
  • Compliant Test Standards: IEC / EN 61000-4-6
  • Application: Four screened, balanced pairs
  • Frequency Range: 150 kHz to 230 MHz
  • RF Input Voltage: 40 V (Max)
  • RF Input Connector: 50 Ω BNC (Female)
  • Voltage Rating: 124 V AC / 125 V DC (Line to Ground)
  • Current Rating: 1.5 Amp (Max)
  • AE and EUT Connections: 50 Ohm Female BNC
Coupling - Decoupling Networks M325E
close
Coupling - Decoupling Networks M325E
04
  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC / EN 61000-4-6
  • Application: Three conductor power cable
  • Frequency Range: 150 kHz to 230 MHz
  • RF Input Voltage: 40 V (Max)
  • RF Input Connector: 50 Ω BNC (Female)
  • Voltage Rating: 250 V AC / 350 V DC (Line to Ground)
  • Current Rating: 25 Amps AC / 17 Amps DC (Max)
  • AE and EUT Connections: 4 mm shrouded banana sockets
Coupling - Decoupling Networks USB-AE
close
Coupling - Decoupling Networks USB-AE
04
  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC / EN 61000-4-6
  • Application: USB cable with type A connector
  • Frequency Range: 150 kHz to 230 MHz
  • RF Input Voltage: 40 V (Max)
  • RF Input Connector: 50 Ω BNC (Female)
  • Voltage Rating: 30 V AC / 30 V DC (Line to Ground)
  • Current Rating: 1 Amp (Max)
  • AE and EUT Connections: EUT: Type A, AE: Type B
Coupling - Decoupling Networks M350E
close
Coupling - Decoupling Networks M350E
05
  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC / EN 61000-4-6, CISPR 16-1-2
  • Application: Three conductor power cable
  • Frequency Range: 150 kHz to 230 MHz
  • I/O rating for EUT/AE Ports: 250 VAC, 350 VDC
  • Max Input Voltage: 40 V (Max)
  • Application: Three wire power cables
  • Current Rating: 50 Amps AC / 35 Amps DC
  • RF Input Connector: 50 Ω BNC (Female)
  • I/O Connection: 5.2 mm banana sockets with shrouded sheath
Coupling - Decoupling Networks USB-BE
close
Coupling - Decoupling Networks USB-BE
05
  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC / EN 61000-4-6
  • Application: USB cable with type A connector
  • Frequency Range: 150 kHz to 230 MHz
  • RF Input Voltage: 40 V (Max)
  • RF Input Connector: 50 Ω BNC (Female)
  • Voltage Rating: 30 V AC / 30 V DC (Line to Ground)
  • Current Rating: 1 Amp (Max)
  • AE and EUT Connections: EUT: Type A, AE: Type B
Coupling - Decoupling Networks M425E
close
Coupling - Decoupling Networks M425E
06
  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC / EN 61000-4-6
  • Application: Four conductor power cable
  • Frequency Range: 150 kHz to 230 MHz
  • RF Input Voltage: 40 V (Max)
  • RF Input Connector: 50 Ω BNC (Female)
  • Voltage Rating: 250 V AC / 350 V DC (Line to Ground)
  • Current Rating: 25 Amps AC / 17 Amps DC (Max)
  • AE and EUT Connections: 4 mm shrouded banana sockets
Coupling - Decoupling Networks M525E
close
Coupling - Decoupling Networks M525E
07
  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC / EN 61000-4-6
  • Application: Five conductor power cable
  • Frequency Range: 150 kHz to 230 MHz
  • RF Input Voltage: 40 V (Max)
  • RF Input Connector: 50 Ω BNC (Female)
  • Voltage Rating: 250 V AC / 350 V DC (Line to Ground)
  • Current Rating: 25 Amps AC / 17 Amps DC (Max)
  • AE and EUT Connections: 4 mm shrouded banana sockets